Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 14 de 14
Filter
1.
J Virol ; 97(6): e0063523, 2023 Jun 29.
Article in English | MEDLINE | ID: covidwho-2327915

ABSTRACT

The stem-loop II motif (s2m) is an RNA structural element that is found in the 3' untranslated region (UTR) of many RNA viruses, including severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Though the motif was discovered over 25 years ago, its functional significance is unknown. In order to understand the importance of s2m, we created viruses with deletions or mutations of the s2m by reverse genetics and also evaluated a clinical isolate harboring a unique s2m deletion. Deletion or mutation of the s2m had no effect on growth in vitro or on growth and viral fitness in Syrian hamsters in vivo. We also compared the secondary structure of the 3' UTR of wild-type and s2m deletion viruses using selective 2'-hydroxyl acylation analyzed by primer extension and mutational profiling (SHAPE-MaP) and dimethyl sulfate mutational profiling and sequencing (DMS-MaPseq). These experiments demonstrate that the s2m forms an independent structure and that its deletion does not alter the overall remaining 3'-UTR RNA structure. Together, these findings suggest that s2m is dispensable for SARS-CoV-2. IMPORTANCE RNA viruses, including severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), contain functional structures to support virus replication, translation, and evasion of the host antiviral immune response. The 3' untranslated region of early isolates of SARS-CoV-2 contained a stem-loop II motif (s2m), which is an RNA structural element that is found in many RNA viruses. This motif was discovered over 25 years ago, but its functional significance is unknown. We created SARS-CoV-2 with deletions or mutations of the s2m and determined the effect of these changes on viral growth in tissue culture and in rodent models of infection. Deletion or mutation of the s2m element had no effect on growth in vitro or on growth and viral fitness in Syrian hamsters in vivo. We also observed no impact of the deletion on other known RNA structures in the same region of the genome. These experiments demonstrate that s2m is dispensable for SARS-CoV-2.


Subject(s)
COVID-19 , RNA Viruses , Viruses , Animals , Cricetinae , SARS-CoV-2/genetics , 3' Untranslated Regions , Mesocricetus , Mutation
2.
Nat Biomed Eng ; 2023 Feb 02.
Article in English | MEDLINE | ID: covidwho-2221821

ABSTRACT

Lateral-flow assays (LFAs) are rapid and inexpensive, yet they are nearly 1,000-fold less sensitive than laboratory-based tests. Here we show that plasmonically active antibody-conjugated fluorescent gold nanorods can make conventional LFAs ultrasensitive. With sample-to-answer times within 20 min, plasmonically enhanced LFAs read out via a standard benchtop fluorescence scanner attained about 30-fold improvements in dynamic range and in detection limits over 4-h-long gold-standard enzyme-linked immunosorbent assays, and achieved 95% clinical sensitivity and 100% specificity for antibodies in plasma and for antigens in nasopharyngeal swabs from individuals with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Comparable improvements in the assay's performance can also be achieved via an inexpensive portable scanner, as we show for the detection of interleukin-6 in human serum samples and of the nucleocapsid protein of SARS-CoV-2 in nasopharyngeal samples. Plasmonically enhanced LFAs outperform standard laboratory tests in sensitivity, speed, dynamic range, ease of use and cost, and may provide advantages in point-of-care diagnostics.

3.
J Clin Microbiol ; 60(6): e0060022, 2022 06 15.
Article in English | MEDLINE | ID: covidwho-1854230

ABSTRACT

Mutations in the genome of SARS-CoV-2 can affect the performance of molecular diagnostic assays. In some cases, such as S-gene target failure, the impact can serve as a unique indicator of a particular SARS-CoV-2 variant and provide a method for rapid detection. Here, we describe partial ORF1ab gene target failure (pOGTF) on the cobas SARS-CoV-2 assays, defined by a ≥2-thermocycle delay in detection of the ORF1ab gene compared to that of the E-gene. We demonstrate that pOGTF is 98.6% sensitive and 99.9% specific for SARS-CoV-2 lineage BA.2.12.1, an emerging variant in the United States with spike L452Q and S704L mutations that may affect transmission, infectivity, and/or immune evasion. Increasing rates of pOGTF closely mirrored rates of BA.2.12.1 sequences uploaded to public databases, and, importantly, increasing local rates of pOGTF also mirrored increasing overall test positivity. Use of pOGTF as a proxy for BA.2.12.1 provides faster tracking of the variant than whole-genome sequencing and can benefit laboratories without sequencing capabilities.


Subject(s)
COVID-19 , SARS-CoV-2 , Base Sequence , Humans , Mutation , SARS-CoV-2/genetics
5.
J Appl Lab Med ; 6(6): 1452-1462, 2021 Nov 01.
Article in English | MEDLINE | ID: covidwho-1493847

ABSTRACT

BACKGROUND: The detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in patient samples is of critical importance in the management of patients and monitoring transmission in the population. However, data on the analytical performance characteristics for detection of SARS-CoV-2 in clinical specimens between individual targets within the same platform, and among different analytical platforms, are limited. METHODS: Here we evaluated the performance of 6 different sample-to-answer SARS-CoV-2 detection methods-Roche cobas 6800, Cepheid GeneXpert, Diasorin Simplexa, Luminex Aries emergency use authorization (EUA), Luminex Aries research use only (RUO), and bioMérieux BioFire-in clinical specimens with a range of viral loads. RESULTS: The positive percentage agreement between the Roche cobas 6800 and GeneXpert was 100%, Diasorin 95%, Aries EUA 74%, Aries RUO 83%, and BioFire 97%. Notably, in samples with cycle threshold (Ct) values below 30 for the E gene on the Roche cobas 6800 platform, we found 100% positive agreement among all platforms. Given these results, we examined the distribution of over 10 000 Ct values of all positive specimens from individuals at our institution on the Roche cobas platform. Nearly 60% of specimens from asymptomatic individuals had a PCR Ct value >30 as measured using the cobas 6800 assay E gene. CONCLUSIONS: Our results demonstrate performance characteristics between different platforms by Ct value and provide data regarding the distribution of viral RNA present in positive specimens.


Subject(s)
COVID-19 , SARS-CoV-2 , COVID-19 Testing , Clinical Laboratory Techniques , Humans , Sensitivity and Specificity
6.
J Appl Lab Med ; 7(3): 727-736, 2022 05 04.
Article in English | MEDLINE | ID: covidwho-1398106

ABSTRACT

BACKGROUND: Saliva has garnered great interest as an alternative specimen type for molecular detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Data are limited on the relative performance of different molecular methods using saliva specimens and the relative sensitivity of saliva to nasopharyngeal (NP) swabs. METHODS: To address the gap in knowledge, we enrolled symptomatic healthcare personnel (n = 250) from Barnes-Jewish Hospital/Washington University Medical Center and patients presenting to the Emergency Department with clinical symptoms compatible with coronavirus disease 2019 (COVID-19; n = 292). We collected paired saliva specimens and NP swabs. The Lyra SARS-CoV-2 assay (Quidel) was evaluated on paired saliva and NP samples. Subsequently we compared the Simplexa COVID-19 Direct Kit (Diasorin) and a modified SalivaDirect (Yale) assay on a subset of positive and negative saliva specimens. RESULTS: The positive percent agreement (PPA) between saliva and NP samples using the Lyra SARS-CoV-2 assay was 63.2%. Saliva samples had higher SARS-CoV-2 cycle threshold values compared to NP swabs (P < 0.0001). We found a 76.47% (26/34) PPA for Simplexa COVID-19 Direct Kit on saliva and a 67.6% (23/34) PPA for SalivaDirect compared to NP swab results. CONCLUSION: These data demonstrate molecular assays have variability in performance for detection of SARS-CoV-2 in saliva.


Subject(s)
COVID-19 , SARS-CoV-2 , COVID-19/diagnosis , Delivery of Health Care , Emergency Service, Hospital , Humans , Nasopharynx , SARS-CoV-2/genetics , Saliva , Specimen Handling/methods
7.
J Clin Microbiol ; 59(7): e0007521, 2021 06 18.
Article in English | MEDLINE | ID: covidwho-1276884

ABSTRACT

Diagnostic assays for detecting severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) are essential for patient management, infection prevention, and the public health response for coronavirus disease 2019 (COVID-19). The efficacy and reliability of these assays are of paramount importance in both tracking and controlling the spread of the virus. Real-time reverse transcription-PCR (RT-PCR) assays rely on a fixed genetic sequence for primer and probe binding. Mutations can potentially alter the accuracy of these assays and lead to unpredictable analytical performance characteristics and false-negative results. Here, we identify a G-to-U transversion (nucleotide 26372) in the SARS-CoV-2 E gene in three specimens with reduced viral detection efficiency using a widely available commercial assay. Further analysis of the public GISAID repository led to the identification of 18 additional genomes with this mutation, which reflect five independent mutational events. This work supports the use of dual-target assays to reduce the number of false-negative PCR results.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , RNA, Viral/genetics , Real-Time Polymerase Chain Reaction , Reproducibility of Results , Reverse Transcriptase Polymerase Chain Reaction , Reverse Transcription , Sensitivity and Specificity
8.
Diagn Microbiol Infect Dis ; 101(2): 115387, 2021 Oct.
Article in English | MEDLINE | ID: covidwho-1193285

ABSTRACT

The Lyra SARS-CoV-2 assay was the primary method for molecular testing performed at Barnes-Jewish Healthcare System in St. Louis, Missouri during the initial COVID-19 surge from mid-March to late-April 2020. We performed a retrospective analysis of 1,043 positive Lyra SARS-CoV-2 results during these 36 days to investigate associations between cycle threshold (CT)  value and patient characteristics. Total RNA were extracted from NP or OP swabs using either the EasyMag or KingFisher automated extraction systems and quantified with RotorGene Q (Qiagen) or Applied Biosystems 7500 Fast Dx thermocyclers respectively. Notably, we found lower a significant median lower CT for samples tested on the KingFisher-ABI 7500 fastDX (KF/ABI) system compared to the EasyMag/RotorGene (EM/RGQ) platform. Since 77.5% of our tests were ran on the EM/RGQ pipeline we then perform additional analysis on these values and found that C T values in outpatient care settings compared to samples obtained in the emergency department or inpatient had significantly lower C T values. These collective findings suggests a difference in viral load amongst various patient populations.


Subject(s)
COVID-19 Nucleic Acid Testing/statistics & numerical data , COVID-19/diagnosis , SARS-CoV-2/isolation & purification , Age Factors , Ambulatory Care/statistics & numerical data , Emergency Medical Services/statistics & numerical data , Hospitalization/statistics & numerical data , Humans , Missouri/epidemiology , Pharynx/virology , Retrospective Studies , SARS-CoV-2/genetics , Viral Load
9.
J Appl Lab Med ; 6(5): 1281-1286, 2021 09 01.
Article in English | MEDLINE | ID: covidwho-1101853

ABSTRACT

BACKGROUND: Widespread testing of SARS-CoV-2 has resulted in shortages of collection devices and transport media. We evaluated the stability of flocked swabs inoculated with SARS-CoV-2-containing specimen incubated dry (i.e., without transport medium) at room temperature. METHODS: A pool of SARS-CoV-2 positive specimen was used to inoculate flocked swabs. Five swabs were placed immediately into universal transport media (UTM) following inoculation, and tested immediately (day 0). Fifteen of the swabs were placed into sterile 15-mL conical tubes and incubated at room temperature for 1, 2, or 7 days. Following incubation, swabs were hydrated in separate vials of UTM and tested. This protocol was repeated for viral transport media (VTM) and saline. As a comparison, a series of swabs was prepared and tested in parallel, but stored in the corresponding liquid transport media (UTM, VTM, or saline) and incubated at room temperature. Testing was performed at 1, 2, and 7 days postinoculation in duplicate. All molecular testing was performed using the Roche cobas SARS-CoV-2 assay. RESULTS: All dry swabs tested on days 1, 2, and 7 provided results that were within 2 cycle thresholds (CTs) of the average CT values for swabs hydrated in the same media and tested on day 0. There was no statistical difference in CT values between swabs incubated in liquid media versus dry swabs incubated at room temperature prior to hydration in liquid media. CONCLUSIONS: The utilization of "dry swabs" may simplify specimen collection, negate the need for liquid transport media, and mitigate safety risks while preserving the accuracy of testing.


Subject(s)
COVID-19 , SARS-CoV-2 , COVID-19 Testing , Humans , Molecular Diagnostic Techniques , Specimen Handling
10.
Best Pract Res Clin Rheumatol ; 35(1): 101660, 2021 03.
Article in English | MEDLINE | ID: covidwho-1056367

ABSTRACT

Laboratory evaluation of SARS-CoV-2 involves the detection of viral nucleic acid, viral protein antigens, and the antibody response. Molecular detection of SARS-CoV-2 is the only diagnostic test currently available in acutely or recently infected individuals. In contrast, serological testing is typically performed once viral RNA has been cleared and symptoms have resolved. This leads to some confusion among clinicians as to which test to order and when each is appropriate. While SARS-CoV-2 assays can suffer from poor sensitivity, all FDA authorized assays to date are intended to be qualitative. Serological tests have multiple assay formats, detect various classes of immunoglobulins, and have a distinct role in seroprevalence studies; however, the association with long-term protection remains unclear. Both molecular and serological testing for SARS-CoV-2 have complementary roles in patient management, and we highlight the challenges faced by clinicians and laboratorians alike in the evaluation and interpretation of the currently available laboratory assays.


Subject(s)
COVID-19 , Pandemics , Humans , Laboratories , SARS-CoV-2 , Sensitivity and Specificity , Seroepidemiologic Studies
11.
J Clin Microbiol ; 59(1)2020 12 17.
Article in English | MEDLINE | ID: covidwho-1048659

ABSTRACT

The distribution of upper respiratory viral loads (VL) in asymptomatic children infected with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is unknown. We assessed PCR cycle threshold (Ct) values and estimated VL in infected asymptomatic children diagnosed in nine pediatric hospital testing programs. Records for asymptomatic and symptomatic patients with positive clinical SARS-CoV-2 tests were reviewed. Ct values were (i) adjusted by centering each value around the institutional median Ct value from symptomatic children tested with that assay and (ii) converted to estimated VL (numbers of copies per milliliter) using internal or manufacturer data. Adjusted Ct values and estimated VL for asymptomatic versus symptomatic children (118 asymptomatic versus 197 symptomatic children aged 0 to 4 years, 79 asymptomatic versus 97 symptomatic children aged 5 to 9 years, 69 asymptomatic versus 75 symptomatic children aged 10 to 13 years, 73 asymptomatic versus 109 symptomatic children aged 14 to 17 years) were compared. The median adjusted Ct value for asymptomatic children was 10.3 cycles higher than for symptomatic children (P < 0.0001), and VL were 3 to 4 logs lower than for symptomatic children (P < 0.0001); differences were consistent (P < 0.0001) across all four age brackets. These differences were consistent across all institutions and by sex, ethnicity, and race. Asymptomatic children with diabetes (odds ratio [OR], 6.5; P = 0.01), a recent contact (OR, 2.3; P = 0.02), and testing for surveillance (OR, 2.7; P = 0.005) had higher estimated risks of having a Ct value in the lowest quartile than children without, while an immunocompromised status had no effect. Children with asymptomatic SARS-CoV-2 infection had lower levels of virus in their nasopharynx/oropharynx than symptomatic children, but the timing of infection relative to diagnosis likely impacted levels in asymptomatic children. Caution is recommended when choosing diagnostic tests for screening of asymptomatic children.


Subject(s)
Asymptomatic Infections/epidemiology , COVID-19/diagnosis , COVID-19/epidemiology , Viral Load , Adolescent , COVID-19 Testing/methods , Child , Child, Preschool , Female , Hospitals, Pediatric , Humans , Infant , Infant, Newborn , Male , Nasopharynx/virology , Oropharynx/virology , SARS-CoV-2/isolation & purification
SELECTION OF CITATIONS
SEARCH DETAIL